Sanzo Power 15 kVA 3-Phase Dry-Type Transformer | 208V delta to 415Y/240 | NEMA 3R | Aluminum

by Sanzo Power · Part # TX-DV-015M-3-320311-AL
4.9 out of 5 · 265 customer reviews(opens the reviews page)

$3,656.00

15 kVA three-phase step-up isolation transformer for 208V delta to 415Y/240 distribution. Aluminum windings, electrostatic shielding and a ventilated NEMA 3R enclosure with individually replaceable bolt-on panels.

Full specifications ↓
This unit is configured to order. We confirm specifications and any customization before invoicing. Request a quote and we will verify the exact build for your application.

Request a Quote

Quotes include a link to approve and pay online — no phone call needed.

Specifications

BrandSanzo Power
Capacity15 kVA
Primary Voltage208V delta
Secondary Voltage415Y/240
PhaseThree Phase
Primary Amperage41.6 A
Secondary Amperage20.9 A
DirectionStep-Up
Frequency60 Hz
Winding MaterialAluminum
Weatherproof RatingNEMA 3R
Insulation System220°C
Temperature Rise150°C
Electrostatic ShieldIncluded
Primary Taps(2) 2.5% Above, (4) 2.5% Below
ConnectionDelta - Wye
Transformer TypeIsolation / Distribution
ConfigurationDry Type, Ventilated
Part #TX-DV-015M-3-320311-AL
CoolingAA / Natural Convection
Enclosure ConstructionBolt-Together; Replaceable Panels
Efficiency at 35% Load97.89%
Dimensions (L x W x H)23.03" L x 22.64" W x 24.61" H
Length (L)23.03"
Width (W)22.64"
Height (H)24.61"
Unit Weight
DutyContinuous, General Purpose
ImpregnationVacuum Pressure Impregnated
Primary TerminationTerminal Lugs
Secondary TerminationTerminal Lugs
Termination AccessFront Access Cover
FinishANSI 61 Grey Powder Coat
Tap RatingFull Capacity; De-energized
CertificationcETLus
StandardsUL 1561 / CSA C22.2 No. 47

Product Description

The Sanzo Power TX-DV-015M-3-320311-AL is a 15 kVA three-phase dry-type isolation transformer that converts 208V delta power to 415Y/240 for commercial and industrial distribution. The grounded-wye secondary supplies 415V three-phase power for equipment loads and 240V line-to-neutral power through an accessible X0 neutral. The separate primary and secondary windings provide electrical isolation.

Construction and enclosure

Aluminum windings, a 220°C insulation system and a 150°C temperature rise support general-purpose distribution duty. An electrostatic shield separates the primary and secondary windings, and natural-air ventilation cools the assembly.

The NEMA 3R steel enclosure supports indoor or outdoor floor mounting. Its bolt-together construction uses individually replaceable panels, allowing a damaged panel or an unwanted conduit opening to be repaired without replacing the complete housing. Upper hooded vents and continuous mounting runners complete the enclosure.

Voltage adjustment and installation

Primary adjustment taps — (2) 2.5% above, (4) 2.5% below nominal — allow the installer to match the winding connection to the incoming supply. This is a purpose-built step-up transformer with H primary terminals and X secondary terminals.

Designed for building distribution, industrial machinery, HVAC systems, pumps and process equipment. Select capacity for the connected load and its starting requirements. Follow the unit wiring diagram for tap selection, grounding and field connections.